Further details are given in the Calibration and stability of the 64-channel dips commissioning report. No  Note that due to a different design, the narrowband modes do not share this effect. No other periodic or spectral leakage effects have been found in the current production release of the correlator (4k wideband coarse and 32k wideband fine modes).